Product Description
Up for sale is a Spot Vital Signs LXi Monitor that is manufactured by Welch Allyn. Item listed does not have cable to test so must be sold as parts or repair. Item has minor surface imperfections. The top left side has a 1/2 inch piece of plastic that cracked.
DESCRIPTION
The Welch Allyn Spot LXi Vital Signs Monitor can be customized to meet the specific needs of you and your facility. Capable of taking vital signs quicker than most other spot-check devices, this top-of-the-line monitor will allow you to spend as much time as you need with your patients. It also boasts the added ease of use and reliability you've come to expect from Welch Allyn devices and it is even compatible with select digital scales.
- Manual weight, height, respiration rate, and pain level entry.
- SureBP standard on all configurations.
- Compatible with some select digital scales.
- Calculates body mass index.
- 50-reading memory.
- Connectivity-ready.
- Fast, accurate, and flexible.
- Extremely easy to use.
Welch Allyn Spot LXi Vital Signs Monitor Specifications
Non-invasive Blood Pressure (NIBP)
- Cuff Pressure Range: 0 to 300 mmHg (0 to 40.0 kPa).
- Systolic Range: 60 to 250 mmHg (8.0 to 33.3 kPa).
- Diastolic Range: 30 to 160 mmHg (4.0 to 21.3 kPa).
- Mean Arterial Pressure Range: 40 to 190 mmHg (5.3 to 25.3 kPa).
- Blood Pressure Accuracy: Meets or exceeds AAMI SP10:2002.
- Overpressure Cutoff: 315 mmHg ± 15 mmHg (42.0 kPa ± 1.9 kPa)
- Blood Pressure Determination Time: Typically 15 seconds.
- Pulse Rate Range: 35 to 199 bpm.
- Pulse Rate Accuracy ± 5.0%.
Temperature
- Temperature Range:
- SureTemp Plus: 26.7 to 43.3 °C.
- Braun ThermoScan PRO 4000: 20 to 42.2 °C.
- Calibration Accuracy:
- SureTemp Plus: ± 0.1 °C (Monitor Mode).
- Braun ThermoScan PRO 4000: ± 0.2 °C to 35.5 °C to 42 °C ± 0.25 °C (outside this temperature range).
- Display Resolution: -17.7 °C.
- SureTemp Plus Predict Time
- Oral: Approx. 4 to 6 seconds.
- Adult Axillary: Approx. 12 to 15 seconds (age 18 years and older).
- Paediatric Axillary: Approx. 10 to 13 seconds (age 17 years and younger).
- Rectal: Approx. 10 to 13 seconds.
- Probe and Probe Well
- Oral/Axillary: Blue.
- Rectal: Red.
SpO2
- Performance Measurement: 1 to 100%.
- Range: 25 to 240 bpm.
- SpO2 Accuracy: 70 to 100%.
- Pulse Rate Accuracy: 25 to 240 bpm ± 3 digits.
MEDICAL
DISCLAIMER
"The sale of this item may be subject to
regulation by the U.S. food and drug administration and state and local
regulatory agencies. If so, you must be an authorized purchaser. If the item is
subject to FDA regulation, I will verify your status as an authorized purchaser
of this item before shipping of the item. Regardless of the origin of this
equipment, documentation provided or identification appearing upon the
equipment, the equipment described and offered here is in no way certified for,
recommended for, or offered for any specific use. The purchaser agrees that the
seller shall not be held responsible or liable for any injuries or damages,
whether incidental or coincidental, associated in any way with the equipment.
The purchaser, by bidding or buying this equipment, indicates their knowledge
of, and agreement to the terms of this disclaimer."
4-3-7