Product Description
Up for sale is a pulse oximeter/blood pressure monitor that is manufactured by Nonin Medical. Item is in used condition. Item was tested and shows signs of power, though no further testing was done. Item has minor surface imperfections, however still in great condition.
Avant® 2120 Specifications
Oxygen Saturation Display Range: 0 to 100% SpO2
Pulse Rate Display Range: 18 to 300 beats per minute (BPM)
Displays:
Numeric Displays: 3-digit LEDs, Tricolor (red, green, amber)
Pulse Indicator: Amber LED
Accuracy – Sensors: Declared accuracy data for compatible sensors can be found in Nonin’s Sensor Accuracy document.
Measurement Wavelengths and Output Power*:
Red: 660 nanometers @ 0.8 mW max. average
Infrared: 910 nanometers @ 1.2 mW max. average
Method of Measurement: Oscillometric
Blood Pressure Range:
Systolic: 40 mmHg to 260 mmHg
Diastolic: 25 mmHg to 200 mmHg
MAP = 1/3 Systolic + 2/3 Diastolic
Pressure Transducer Accuracy: ±3 mmHg between 0 mmHg and 300 mmHg for operating conditions between 0 °C and 50 °C. (S.D. of 8 mmHg)
Recommended Frequency of Pressure Transducer Calibration:
The Pressure Transducer calibration should be verified yearly or every 10,000 readings, whichever comes first.
Pulse Rate Range: Up to 200 pulses per minute (BPM) [displayed if there is no value from the oximeter]
Blood Pressure Altitude: -170 to 12,000 m
Temperature:
Operating: 32 °F to 122 °F (0 °C to 50 °C)
Storage/Transportation: -40 °F to 158 °F (-40 °C to 70 °C)
Humidity:
Operating: 10% to 90% noncondensing
Storage/Transportation: 10% to 95% noncondensing
Power Requirements: (NOT INCLUDED)
Mains: 100-240 VAC 50-60 Hz
DC Input: 12 VDC 1.5A AC power supply
Internal Power:
Battery: 7.2 volt battery pack (6 cells)
Operating Life: minimum 5 hours of continuous operation
Storage Life: 18 days
Recharge Time: 4 hours with device off
Memory: 33.5 hrs (assuming continuous operation)
Alarm Volume Range: 55–81 dBA
Informational Tone Volume Range: 50–70 dBA
Altitude:
Operating: Up to 40,000 feet (12,192 m)
Hyperbaric Pressure: Up to 4 atmospheres
Dimensions: 4.5 x 7.5 x 5.4 in. (11.4 x 19.0 x 13.8 cm)
Weight: 45.3 oz. (1.28 kG) with batteries
Classification per IEC 60601-1 / CAN/CSA-C22.2 No. 601.1 / UL60601-1:
Type of Protection: Class II (when on AC power with MPP30 power supply) Internally powered (on battery power)
Degree of Protection: Type BF-Applied Part (pulse oximeter).
Defibrillation-Proof Type BF Applied Part (NIBP).
Enclosure Degree of Ingress Protection: IPX2
Mode of Operation: Continuous
MEDICAL
DISCLAIMER
"The sale of this item may be subject to
regulation by the U.S. food and drug administration and state and local
regulatory agencies. If so, you must be an authorized purchaser. If the item is
subject to FDA regulation, I will verify your status as an authorized purchaser
of this item before shipping of the item. Regardless of the origin of this
equipment, documentation provided or identification appearing upon the
equipment, the equipment described and offered here is in no way certified for,
recommended for, or offered for any specific use. The purchaser agrees that the
seller shall not be held responsible or liable for any injuries or damages,
whether incidental or coincidental, associated in any way with the equipment.
The purchaser, by bidding or buying this equipment, indicates their knowledge
of, and agreement to the terms of this disclaimer."
23-1-4