Product Description
Up for sale is a Circuit Breaker that is manufactured by Heinemann Electric Co. Item listed shows signs of prior usage.
Additional Features:
AEBP | Center to Center Distance Between Terminals Parallel to Length | 3.546 inches nominal |
AEBQ | Center to Center Distance Between Terminals Parallel to Width | 1.032 inches nominal |
AEBY | Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.750 inches nominal |
AEHA | Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 1.032 inches nominal |
AJWX | Mounting Surface to Terminal End Distance | 2.609 inches nominal |
AKPX | Pole Quantity | 4 |
APNQ | ARC Quenching Method | Magnetic blowout |
AXHR | Mounting Facility Type and Quantity | 8 threaded hole and 8 slot |
BBRG | Storage Type | General purpose warehouse |
BBRJ | Special Handling Feature | Magnetic |
CMLP | Thread Quantity per Inch | 32 |
CPLM | Maximum Continuous Load Current Rating per Pole | 60.0 amperes ac second location |
CPLM | Maximum Continuous Load Current Rating per Pole | 60.0 amperes ac third location |
CPLM | Maximum Continuous Load Current Rating per Pole | 60.0 amperes ac fourth location |
CPRF | Operating Voltage Type and Rating per Pole in Volts | 107.0 dc first location |
CPRF | Operating Voltage Type and Rating per Pole in Volts | 240.0 ac fourth location |
CPRF | Operating Voltage Type and Rating per Pole in Volts | 240.0 ac third location |
CPRF | Operating Voltage Type and Rating per Pole in Volts | 240.0 ac second location |
CPRG | Maximum Interrupting Capacity Current Type and Rating per Pole in Amps | 5000.0 ac third location |
CPRG | Maximum Interrupting Capacity Current Type and Rating per Pole in Amps | 5000.0 ac fourth location |
CPRG | Maximum Interrupting Capacity Current Type and Rating per Pole in Amps | 5000.0 ac second location |
CPRH | Circuit Protection Type | Overcurrent second location |
CPRH | Circuit Protection Type | Overcurrent third location |
CPRH | Circuit Protection Type | Overcurrent fourth location |
CPRH | Circuit Protection Type | Undervoltage first location |
CPRJ | Trip Release Method | Magnetic-hydraulic fourth location |
CPRJ | Trip Release Method | Magnetic-hydraulic second location |
CPRJ | Trip Release Method | Magnetic-hydraulic third location |
CPRJ | Trip Release Method | Magnetic first location |
CPRL | Trip Release Characteristic | Instantaneous first location |
CPRL | Trip Release Characteristic | Time delay fourth location |
CPRL | Trip Release Characteristic | Time delay second location |
CPRL | Trip Release Characteristic | Time delay third location |
CPRN | Ultimate Trip Rating of Continuous Current Rating per Pole in Percent | 140.0 fourth location |
CPRN | Ultimate Trip Rating of Continuous Current Rating per Pole in Percent | 140.0 second location |
CPRN | Ultimate Trip Rating of Continuous Current Rating per Pole in Percent | 140.0 third location |
CPRQ | Reset Method | Manual |
CPRR | Main Contact Tripping Mechanism Type | Trip free |
CPRT | Manual Actuator Type and Quantity | 4 toggle |
CPRW | Actuator Function | Trip-reset |
CPRX | Actuator Position Designation | At each pole |
CPRY | External Actuator Linkage Arrangement | One, two, three, and four linked |
CPSM | Internal Trip Release Configuration | Series trip all locations |
CQJX | Nominal Thread Size | 0.138 inches |
CQWN | Trip Delay Time in Seconds per Rated Continuous Current | 4.000 minimum at 200 pct fourth location and 10.000 maximum at 200 pct fourth location |
CQWN | Trip Delay Time in Seconds per Rated Continuous Current | 4.000 minimum at 200 pct second location and 10.000 maximum at 200 pct second location |
CQWN | Trip Delay Time in Seconds per Rated Continuous Current | 4.000 minimum at 200 pct third location and 10.000 maximum at 200 pct third location |
CQXF | Inclosure Protection Type for Which Designed | Fungus resistant and moisture resistant |
FEAT | Special Features | Four terminals on pole one |
FREQ | Frequency in Hertz | 400.0 second location |
FREQ | Frequency in Hertz | 400.0 third location |
FREQ | Frequency in Hertz | 400.0 fourth location |
TEST | Test Data Document | 49956-G166010 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) |
THSD | Thread Series Designator | UNC |
TTQY | Terminal Type and Quantity | 10 threaded stud |